Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anal Biochem ; 434(1): 178-80, 2013 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-23201266

RESUMO

The Bradford assay is a simple method for protein quantitation, but variation in the results between proteins is a matter of concern. In this study, we compared and normalized quantitative values from two models for protein quantitation, where the residues in the protein that bind to anionic Coomassie Brilliant Blue G-250 comprise either Arg and Lys (Method 1, M1) or Arg, Lys, and His (Method 2, M2). Use of the M2 model yielded much more consistent quantitation values compared with use of the M1 model, which exhibited marked overestimations against protein standards.


Assuntos
Modelos Teóricos , Proteínas/análise , Corantes de Rosanilina/química , Espectrofotometria , Peptídeos beta-Amiloides/química , Peptídeos beta-Amiloides/metabolismo , Animais , Arginina/química , Bovinos , Histidina/química , Humanos , Insulinas/química , Insulinas/metabolismo , Lisina/química , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismo , Ligação Proteica , Proteínas/metabolismo , Ratos , Corantes de Rosanilina/metabolismo , Albumina Sérica/química , Albumina Sérica/metabolismo
2.
J Chromatogr A ; 1218(38): 6596-602, 2011 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-21840008

RESUMO

We describe an accurate method for protein quantification based on conventional acid hydrolysis and an isotope dilution-HPLC-mass spectrometry (ID-HPLC-MS) method. Sample purity was confirmed using capillary zone electrophoresis, HPLC and MS. The analyte protein, human growth hormone (hGH), was effectively hydrolyzed by incubation with 8 M hydrochloric acid at 130 °C for 48 h, where at least 1 µM of hGH was treated to avoid possible degradation of released amino acids during hydrolysis. Using a reversed-phase column, the analytes (isoleucine, phenylalanine, proline and valine) were separated within 5 min using an isocratic eluent comprising 10% acetonitrile containing 0.1% trifluoroacetic acid. The detection limit (signal to noise ratio of 3) of amino acids was 5.5-6.2 fmol per injection. The quantification precision (RSD) of amino acids for intra- and inter-day assays was less than 0.98% and 0.39%, respectively. Comparison with other biochemical and instrumental methods revealed substantially higher accuracy and reproducibility of the ID-HPLC-MS/MS method as expected. The optimized hydrolysis and analytical conditions in our study were suitable for accurate quantification of hGH.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Hormônio do Crescimento Humano/química , Técnicas de Diluição do Indicador , Mapeamento de Peptídeos/métodos , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Humanos , Hidrólise , Dados de Sequência Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA